An eleven-bedroom HMO conversion in Hornsey has failed after an Inspector found that losing a residential care home would harm local social care provision.
Inspector F Harrison dismissed Havenport Estates Ltd’s appeal against non-determination by Haringey Council on 23 November 2026, refusing the proposed rear extensions and change of use.
The decision also found insufficient evidence of internal space and fire safety, although the proposed shared accommodation was not expected to worsen neighbouring residents’ living conditions.
The case on Endymion Road is worth noting because the loss of a care home was assessed as a community infrastructure issue rather than simply a housing conversion.
Why the HMO conversion failed the community test
The Inspector assessed the proposal as submitted without formally determining the lawful existing use of the building, which was outside the remit of the appeal.
Haringey’s Development Management DPD Policy DM49 protects community infrastructure and requires evidence before the loss of a facility can be accepted.
That evidence needs to address whether the facility is still required, whether its loss would leave a shortfall, and whether the current use remains viable.
The policy also requires consideration of demand for another suitable community use on the site.
Although the supporting local policy does not expressly list care homes, the Inspector considered that specialist accommodation performs a social care function for the community.
The council considered this type of accommodation to be a valued resource in short supply, and the appellant’s evidence did not adequately address the loss.
Paragraph 6 concludes: “I cannot be confident therefore that the proposal would protect the needs of the community.”
Room layouts and fire safety
The extension would create another bedroom of 14 square metres for single occupation, but the drawings did not give room sizes or occupation details for every bedroom.
Without furniture layouts, the Inspector could not establish whether residents would have enough space for basic furniture and comfortable circulation.
There would be no communal living room, making the functional layout of each bedroom particularly important, and the two proposed kitchens were narrow and awkwardly shaped.
The Inspector also considered that the evidence did not demonstrate suitable means of escape under London Plan Policy D12, irrespective of the council’s application validation requirements.
Our HMO planning application guide explains why a detailed application needs more than an indication of how many bedrooms can be fitted into a property.
Licensing under housing legislation is a separate regime, so compliance with licensing standards does not establish that planning permission should be granted.
Why noise was not a reason for refusal
The Inspector compared the likely movements of HMO residents and visitors with those of care staff, healthcare professionals, deliveries and family visits associated with the existing use.
Those patterns of activity were not expected to produce materially greater noise or disturbance, and the modest garden did not justify a different conclusion.
A management plan could also have been secured by condition if permission had been granted.
The benefit of additional housing choice was recognised, but the adverse effects on social care provision and future occupants substantially outweighed that benefit.
For anyone considering a similar HMO conversion, evidence of the need for the existing facility deserves attention alongside the proposed bedroom and kitchen layouts.
Read the official appeal record for reference 6010248 and application HGY/2025/2487.